Blue PUCK T-PROBE + 1 hour free support (PPEX00000780)
Extend device limits with new Bluetooth 4.0 LE Wide range Temperature sensor. One hour free technical support
Código de artículo VAR-827001010
Description
It can be used for other cold chain logistics solutions like freezers, refrigerators. Sensor is EN12830-2018 certified. Sensor uses advanced Bluetooth 4.0 BLE technology to get data from long distance and can work from internal battery up to 15 years! Collected temperature information of the surrounding environment is transferred to FMB device which has possibility to support up to four temperature sensors at the same time!
Mirifica added value:
- One hour free technical support per email
Long transmission range, up to 500 meters (open field)
Long battery life time, up to 15 years
Easy configuration with dedicated mobile application via NFC
Standard order codes
Product code | Region | Package contains |
---|---|---|
258-00117 | World Wide market | Blue PUCK T-PROBE Temperature Sensor |
Identificación de artículo | 100822 |
Estado | |
Modelo | PPEX00000780, PGEX00000780 |
Fabricante | Teltonika |
País de origen | |
Contenido | 1 undefined |
Features
TECHNICAL DATA | |
---|---|
Battery | Lifecycle up to 15 years (Beacon rate: 3 s / Power: +4 dBm / Download: 4000 values per day / Temperature: one measurement every 10 seconds) |
Operating mode | “Advertising” beacon mode: periodic data transmission (id + sensor data) Online mode: download up to 4,000 stored values |
Bluetooth | 2,4 GHz - Bluetooth Low Energy 4.0/4.2 |
NFC | Secured NFC programming |
Puck dimensions | Ø 57mm base - Thickness 20mm |
Probe dimesnions | Ø 3 mm, Lenght 28 mm, M8, 1 m cable |
Weight | 63 g |
Operating temperature | PUCK housing : -40°C to +85°C Probe : -80°C to +200°C |
Ingress Protection Rating | IP68 (Waterproof) |
Probe measuring range | -80°C to 200°C |
Accuracy | ±0.5 °C maximum (-30°C to +60°C) /±1 °C maximum (-40°C to +150°C) / ±2 °C maximum (-80°C to +200°C) |
Calibration | Parametric calibration coefficients (Polynomial 2 °) |
Resolution | 0,1°C |
Transmission range | Up to 500 meters (open field) |
Transmission period | 0,1 to 10 second (programmable) |
Regulatory | CE (Europe): EN 300 328/EN 301 489 & EN 55032/EN 62368-1 FCC (USA): FCC PART 15 ISED (Canada): RSS-247/ICES-003 RoHS EN12830 - 2018 |