Häufig aufgerufene Artikel

Digilent Inc.

Digilent MCC USB-2404-UI: Universal Input USB DAQ Device

USB-2404-UI from Measurement Computing has four simultaneous analogue inputs for measuring voltage, current, thermocouples, RTDs, resistance and bridge-based sensors.


Artikelnummer VAR-827003878

Hersteller-Teilenummer: 6069-410-035

Taric/custom code:


Verfügbar für sofortigen Versand: 0

Ausführungsfristen 3 Tage. Für Bestellungen mit einem Gesamtnettowert von weniger als 70 Euro berechnen wir eine Bearbeitungsgebühr von 20 Euro.

Importierter Artikel wird versendet ab D-Riedlingen.


1.113,08 EUR *
Inhalt 1 Stück


Loggen Sie sich ein und erhalten Sie bessere Preise. Oder kontaktieren Sie uns und fragen Sie nach dem B2B-Status .

* Exkl. MwSt. exkl. Versandkosten

The Measurement Computing USB-2404-UI features four simultaneous analog inputs capable of measuring voltage, current, thermocouples, RTDs, resistance, and bridge-based sensors. This device features an A/D per channel and includes channel-to-channel and system to host isolation. This device is USB-powered and requires no external power.

The USB-2404-UI provides four individually configurable channels of 24-bit universal analog input with integrated signal conditioning. All channels are measured simultaneously at up to 100 S/s per channel.

The USB-2404-UI can perform the following measurements:
Voltage (60 V, 15 V, 4 V, 1 V, 125 mV)
Current
Thermocouple
RTD (4-wire and 3-wire)
Resistance (4-wire and 2-wire)
Bridge-based sensors (quarter-, half-, and full-bridge)
Measurement ranges vary for each type of measurement.

The USB-2404-UI features built-in current and voltage excitation. The excitation circuit is protected from overcurrent and overvoltage fault conditions. The USB-2404-UI supports class II TEDS smart sensors, and includes a built-in thermistor for cold-junction compensation (CJC). An analog pre-filter removes noise that may be present in the signals prior to conversion.

The following timing options are supported. Each option is optimized for different types of applications by using different ADC conversion times.
High Speed Optimized for high-speed applications at the expense of noise rejection.
Best 60 Hz Rejection Optimized for rejection of 60 Hz noise.
Best 50 Hz Rejection Optimized for rejection of 50 Hz noise.
High Resolution Optimized for maximum overall noise rejection, and provides a good rejection of both 50 Hz and 60 Hz noise.

Each channel has a 6-position detachable spring connector for field wiring connections.
Software support includes TracerDAQ, an included out-of-the-box application for data logging, visualization, and signal generation. Data can be viewed in real-time or post-acquisition on user-configurable displays. Drivers are included for the most popular applications and programming languages including Visual C++, Visual C#, Visual Basic.NET, DASYLab, LabVIEW, and Python.

Digilent products are warranted to be free from manufacturing defects for 30 days from the date of purchase. No other express or implied warranties are provided.

Key Features

  • 4 simultaneous analog inputs
  • 24-bit resolution
  • 100 S/s/ch sample rate
  • Universal inputs measure voltage, current, thermocouples, RTDs, resistance, and bridge-based sensors
  • 60 V, 15 V, 10 V, 4 V, 1 V, 125 mV input ranges
  • 250 Vrms channel to channel isolation
  • no external power supply required

Project Links

Scope of Delivery

  • MCC USB-2404-UI
  • USB cable
  • Printed insert:Software Quick Start
  • MCC packaging assembly/foam, etc.

References

  • Manufacturer: DigilentInc.
  • Manufacturer'sarticle name: USB-2404-UI: Universal Input USB DAQ Device
  • Manufacturer's article number: 6069-410-035

Resources

Other Digilent products are available on request.

Technisches Merkmal Wert
Art.-ID 103497
Zustand Neu
Legacy item ID 0196900fdf56712d8d8160d71dd2d3b2
Modell 6069-410-035
Hersteller Digilent Inc.
Herstellungsland Taiwan
Inhalt 1 Stück